CoryOndrejka
6 hours ago
Dropped rods are an incident but one that occurs because of pressurized water reactors being very default safe. Controls rods are one way the criticality of a reactor is controlled and US reactors (in general) will go sub critical if even one rod is fully inserted into the core. You will likely have heard of a reactor scram (which goes back to the safety control rod ax man) where in an emergency, all the rods are dropped back into the core, greatly reducing its criticality. In some cases, an interruption of electrical power will cause a rod (or three) to drop accidentally. This is a "dropped rod" incident and will force a reactor shut down because it is now sub critical.
Lots of knock on effects -- sub critical, let heat in the primary loop, less steam and electricity generated in the secondary loop, etc -- but generally a non event that you practice for.
There's no reason this would lead to a radiological event or more significant casualty.
anonymousiam
a few seconds ago
There's a difference between control rods (which are used to reduce fission by absorbing neutrons) and fuel rods (which contain enriched fissile material). In this case, the control rods that fell into the core would pose no risk at all to anybody, but would inhibit the ability of the reactor to reach full capacity.
thinkcontext
4 hours ago
Maybe a non-event for safety but what about getting the plant operating again?
CoryOndrejka
3 hours ago
I don't know this plant. In navy submarine reactors like the S5W, you have 440V/3-phase power holding the clamp. If you dropped a rod due to a power or clamp malfunction, usually you'd simply shut down the reactor, drop all the rods and mechanically re-engage the clamp. It could take a few hours which isn't fun because no power which probably means submarine/snorkel depth to run the incredibly noisy diesel, but no step was particularly hard or dangerous.
mlsu
2 hours ago
Now I’m curious. What if it occurs when you’re like under the enemy and you can’t surface? Do you have to just chill at depth until you can get the reactor running again?
Angostura
an hour ago
The final paragraph of the article
> According to NextEra Energy, Unit 1 at St. Lucie is back online at 100% power after operators safely resolved an equipment issue.
I wish the article had said where on earth St Lucie is. Never heard of it
billygoat
28 minutes ago
This St. Lucie is in Florida USA, on the Atlantic coast north of Palm Beach and south of Orlando.
eastbound
an hour ago
St Lucie: Island in the South of the Caribbean. Source: lunch games https://worldlegame.io https://flagle.org
roughly
3 hours ago
Almost certainly a better problem to have.
xattt
2 hours ago
OG article makes it seem the control rods detached/broke off from an actuator mechanism right into the core.
As someone who’s had to fish out things from awkward places (and sometimes to lose them again right after), I started wondering how they’d be getting it out.
recursivecaveat
an hour ago
What what I can tell they use "dropped" to refer to just falling to the bottom of their shaft, though it definitely does evoke the idea of them just rattling around down there in my head. I think that since water is such a good buffer, that once you turned off the pressure you could open a hatch and just kind of fish out whatever you wanted with a very long pair of tongs. This is obviously a research sized reactor, but you can see they're happily mucking about with it on the other end of long poles, and the scientist says they could hypothetically fish something back out: https://youtu.be/5QcN3KDexcU?t=329
jwkpiano1
5 hours ago
In case you weren’t aware, the “safety control rod ax man” thing is aprocryphal and almost certainly not reflective of the origins of the term.
wahern
5 hours ago
It's one of the more truthy backronyms. There was an actual ax man with an ax whose job was to cut a rope to let loose the control rods, and they did use the (existing, apt) word, scram, for the emergency procedure: https://en.wikipedia.org/wiki/Scram
CoryOndrejka
4 hours ago
Exactly what I would have answered :)
jwkpiano1
3 hours ago
None of this contradicts the point I was making, which is that the OP implied that’s what the term meant, and it simply isn’t.
Onavo
5 hours ago
Simpson's?
sandworm101
3 hours ago
Well, we don't know exactly why the reactor was manually shut down. Did the person actually know that the control rods had dropped? Or was it reported by sensors? I suspect the procedure us to initiate shutdown in response to any reports of uncommanded rod behavior. I doubt they would wait around to see if this was a sensor or reporting system error.
CoryOndrejka
3 hours ago
The dropped rods already shut down the reactor in the sense that it is sub critical. It still has enough leftover heat that it will continue to produce steam for a while, but it would have been almost instantly clear to the operators what had happened.
CoryOndrejka
3 hours ago
[Correction] as noted below, this type of reactor -- unlike US Navy ones -- can remain critical even with dropped rods. So a better statement here would be that the operators would immediately notice a reduction in criticality. thus power and heat. Then it's a process/policy question about shutdown timing.
sandworm101
2 hours ago
Navy reactors are physically tiny. A rod in a reactor the size of a garbage can means much more than a rod in a reactor the size of a studio apartment.
metalman
5 hours ago
Thats a releaf, nothing like an uncontrolled saftey event to take a bit of pressure off
joebig
6 hours ago
I think you said it: it's a non-event. It's the reactor reactor-ing within the design basis. But, I think "single rod-drop" will not shut down a reactor. That's a crazy amount of rod-worth. My opinion is that reactor safe-shutdown margin entails "single rod-stuck" scram to be feasible.
MBCook
3 hours ago
> But, I think "single rod-drop" will not shut down a reactor
Why do you think that? When rods are used to control the reaction rate I thought it was by raising and lowering them small amounts usually.
Being able to have a single fully inserted rod stop things would certainly make it more likely dropping rods into the core would stop an even than if you needed (say) all 3 to be fully inserted.
3x the chance of successfully stopping a serious problem, 1/3rd the chance of a blockage prevent the emergency shutdown.
joebig
3 hours ago
I'm already getting downvoted to oblivion for my gp comment, but whatever: what I was trying to convey based on my limited exposure is that a single rod will have a zone restricted shadow or local effect and multiple uniformly distributed rod banks are therefore needed for a an effective control or emergency shutoff. Additionally, on the flip side, I feel a single rod capable of shutoff will insert excessive positive reactivity in case of an ejection (could be a local steam overpressure, idk, don't hunt me down with hounds).
s1artibartfast
3 hours ago
Why don't you just look it up instead of actively arguing an assumption?
This reactor type has 73 assemblies of 5 rods each.
Nuclear safety regulations require that the control rod system must be powerful enough to bring the reactor completely subcritical with all Control Element Assemblies (CEAs) inserted minus one assembly stuck in the fully withdrawn position.
One assembly (or 3) inserted would not bring the reactor subcritical.
CoryOndrejka
3 hours ago
Yup, this is me focusing on US Navy reactors, which is my experience. For them, a rod would already take you sub critical.
kryogen1c
5 hours ago
>generally a non event
depends on what your priors are. Is a dropped rod a fukashima or chernoble international emergency? No.
However, depending on the design characteristics of the core, dropping rods lowers the heat distribution proximal to the dropped rod(s), but may result in higher peaks distal to the rods as physics characteristics attempt to maintain the average, which may exceed design limits.
Furthermore, rods aren't supposed to drop. How that came to pass is a matter that requires honest investigation - manufacturing/quality control, maintenance practices, personnel error? Much to learn to ensure safety.
Saying "we just had to rely on a critical reactor safety feature and scrammed, this is a nonevent" doesnt quite hit the mark.
CoryOndrejka
4 hours ago
Of course, but that's not what happened here. For a pressurized water reactor, there are maintenance and procedural questions about why the rod was dropped. People will likely get fired over this. But from a standpoint of reactor and radiological safety, this is largely the design operating correctly and prioritizing radiological containment.
CoryOndrejka
4 hours ago
and for the curious who didn't what Chernobyl on HBO, other types of reactors have brief criticality increases on rod insertion, which is somewhere between bad, BAD, and OMFGWTFBBQVERYBAD. In the Chernobyl's case, they entered a criticality region known as "prompt criticality" which is where power doubling can happen at prompt neutron rates (e.g. milliseconds or faster). Very very bad. In the case of pressurized water reactors, this isn't what happens. Every moment of control rod descent is reducing criticality.
kryogen1c
3 hours ago
> Of course, but that's not what happened here
They dropped rods and had to scram, unclear what part of that you think is not relying on a safety feature. Why do you think they scrammed?
>this is largely the design operating correctly and prioritizing radiological containment.
Is that largely what is was, or entirely what it was? Im not sure what your point is.
> there are maintenance and procedural questions about why the rod was dropped.
I agree, that's why I said it.
> People will likely get fired over this.
I dont know why youre telling me this, you're the one that called this a nonevent
consensus1
2 hours ago
The entire point of critical safety features is to turn events into non events.